{"product_id":"tramex-cdik-concrete-determinator-inspector-kit","title":"Concrete Determinator Inspector Kit","description":"\u003cdiv class=\"card__header\" data-mce-fragment=\"1\"\u003e\n\u003ch2 class=\"card__title heading h3\" data-mce-fragment=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card__section expandable-content expandable-content--expandable\" aria-expanded=\"true\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"rte text--pull\" data-mce-fragment=\"1\"\u003e\n\u003ch1 data-mce-fragment=\"1\"\u003eTramex CDIK Concrete Determinator Inspector Kit\u003c\/h1\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eThe Tramex Concrete Moisture Probe, The Determinator, extends the capabilities of the Tramex Concrete Moisture Encounter range\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Tramex Concrete Moisture Probe, The Determinator, extends the capabilities of the Tramex Concrete Moisture Encounter range, providing in-situ Moisture Content readings in a Tramex Unified Moisture Content Test Method of quantitative Moisture Content measurements in both the top 19mm (¾ inch) layer and within the body of concrete floors and slabs down to an extendable depth of up to 100mm (4\").\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Concrete Moisture Probe can be used with the CME5, CMEX5 and older Concrete Moisture Encounters CME4 and CMEX2. The Determinator is supplied in a Tramex hard case with allocated space for your Tramex Concrete Moisture meter.\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eHow It Works\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Concrete Moisture Probe when used with Tramex CME instruments operates on the principle that the electrical impedance of a material varies with its moisture content.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe CME instrument is pressed onto the CMP cradle which is pressed onto the material surface with the pins fully compressed and the probe inserted into the pre-drilled 19mm (¾ inch) hole to measure\/ detect the moisture content.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe electrical impedance is measured by creating a low frequency alternating electric field between the electrodes and the probe, to a depth of up to 100mm (4”).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis field penetrates the material under test. The very small alternating current flowing through the field is inversely proportional to the impedance of the material. The instrument detects this current, determines its amplitude, and thus derives the moisture value.\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eOperating Procedures\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Determinator cradle should be flat on the slab surface and the Tramex Concrete Moisture Encounter placed and firmly pressed onto the cradle. The probe reads from the bottom, within the body of the slab, up to the surface.\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eKit Contents\u003c\/h2\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConcrete Moisture Encounter X5 - CMEX5.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFree App available for Android and iOS (phone not included).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConcrete Moisture Determinator Probe.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e1 x Hygro-i2 ® Reusable Relative Humidity probe.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCalibration Check Plate.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInfrared Thermometer.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHole liners.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eExtension Handle.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHard Shell Carry Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eConcrete Moisture Encounter X5 - CMEX5 - Measuring Range:\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eDepth of penetration in concrete:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eapprox. 20mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eMoisture content for Concrete:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0 → 6.9 %\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eComparative for Gypsum floor screed:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0 → 12\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eCM Equiv Anhydrite\/Concrete:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0→2.7 \/ 0→4.3\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReference scale:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0 → 100\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eRelative Humidity: \u003c\/strong\u003e0 → 99%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eRelative Humidity with optional Hygro-i2 ® probe:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0% → 99%RH +\/- 2% @ 25°C \/ 77°F\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eMoisture content for wood (with optional wood pin probes): \u003c\/strong\u003e5 → 30 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eConcrete Moisture Probe, The Determinator - Measuring Range:\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eMoisture Content for Concrete with Tramex CMEX5:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0 - 6.9%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eDepth of Penetration:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e3cm probe depth for concrete between 5-10cm\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e5.7cm probe depth for concrete between 10-15cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e8.3cm probe depth for concrete between 15-22cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e10.8cm probe depth for concrete between 22-28cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eInfrared Thermometer IRT2\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eTemperature range: \u003c\/strong\u003e-50 to 650 ºC (-58ºF ~ 1202ºF)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eDistance to Spot ratio:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eD:S = 12:1\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eDisplay resolution:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0.1 ºC(0.1ºF) \u0026lt;1000 1ºC \u0026gt;1000\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAccuracy for targets: \u003c\/strong\u003eAssumes ambient operating temperature of 23 to 25 ºC (73 to 77ºF) -50 ~ 20ºC (-58ºF ~ 68ºF) ±2.5ºC(4.5ºF) 20ºC ~300ºC (68ºF ~572ºF) ±1.0% ±1.0ºC (1.8ºF) 300ºC ~650ºC (572ºF ~ 1202ºF) ±1.5%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eRepeatability: \u003c\/strong\u003e-50~20ºC (-58~68ºF) : ±1.3ºC (2.3ºF) 20~650ºC (68~1202ºF): ±0.5% or ±0.5ºC (0.9ºF)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eResponse time: \u003c\/strong\u003e150ms\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpectral response:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e8~14um\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eEmissivity:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eDigitally adjustable from 0.10 to 1.0\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eOver range indication:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLCD will show “----”\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003ePolarity:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAutomatic (no indication for positive polarity); Minus (-) sign for negative polarity\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eDiode laser output:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u0026lt;1mW,Wavelength 630~670nm, Class 2 laser product\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eOperating temp.:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0 to 50ºC(32 to 122ºF)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eStorage temp.:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e–10 to 60ºC (14 to 140ºF)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eRelative humidity:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e10%~90%RH operating, \u0026lt;80%RH storage\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003ePower supply:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e9V battery, NEDA 1604A or IEC 6LR61, or equivalent\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSafety: \u003c\/strong\u003e\"CE\" Comply with EMC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eSpecifications Of Kit:\u003c\/h2\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSize: 43.5cm x 36cm x 14cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeight: 2.95kg\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePower: 2 x AA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tramex","offers":[{"title":"Default Title","offer_id":40675745661121,"sku":"CDIK","price":3550.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/3138\/8353\/products\/TramexInfraredSurfaceThermometer-IRT21_600x_63636f0a-32ad-4fa4-b6d5-7414268928e9.jpg?v=1630898915","url":"https:\/\/moisturemeterexperts.com.au\/products\/tramex-cdik-concrete-determinator-inspector-kit","provider":"Moisture Meter Experts","version":"1.0","type":"link"}