{"product_id":"tramex-cdk-concrete-determinator-kit","title":"Concrete Determinator Kit","description":"\u003cdiv class=\"card__header\" data-mce-fragment=\"1\"\u003e\n\u003ch2 class=\"card__title heading h3\" data-mce-fragment=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card__section expandable-content expandable-content--expandable\" aria-expanded=\"true\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"rte text--pull\" data-mce-fragment=\"1\"\u003e\n\u003ch1 data-mce-fragment=\"1\"\u003eTramex CDK Concrete Determinator Kit\u003c\/h1\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eThe Tramex Concrete Moisture Probe, The Determinator, extends the capabilities of the Tramex Concrete Moisture Encounter range\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Tramex Concrete Moisture Probe, The Determinator, extends the capabilities of the Tramex Concrete Moisture Encounter range, providing in-situ Moisture Content readings in a Tramex Unified Moisture Content Test Method of quantitative Moisture Content measurements in both the top 19mm (¾ inch) layer and within the body of concrete floors and slabs down to an extendable depth of up to 100mm (4\").\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Concrete Moisture Probe can be used with the CME5, CMEX5 and older Concrete Moisture Encounters CME4 and CMEX2. The Determinator is supplied in a Tramex hard case with allocated space for your Tramex Concrete Moisture meter.\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eHow It Works\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Concrete Moisture Probe when used with Tramex CME instruments operates on the principle that the electrical impedance of a material varies with its moisture content.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe CME instrument is pressed onto the CMP cradle which is pressed onto the material surface with the pins fully compressed and the probe inserted into the pre-drilled 19mm (¾ inch) hole to measure\/ detect the moisture content.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe electrical impedance is measured by creating a low frequency alternating electric field between the electrodes and the probe, to a depth of up to 100mm (4”).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis field penetrates the material under test. The very small alternating current flowing through the field is inversely proportional to the impedance of the material. The instrument detects this current, determines its amplitude and thus derives the moisture value.\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h2\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInstant and Accurate\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDesigned to work in the same drill-hole made for the F2170 test.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEliminate confusion between in-situ Relative Humidity tests and surface Moisture Content tests.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDetermine if moisture is coming from below or above the concrete slab surface.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDetermine the type and extent of mitigation if needed.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReusable, Extendable, and requires no plastic hole liners.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCan be used in conjunction with Tramex Concrete Moisture Encounters CME5, CMEX5, (CME4 and CMEX2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eProduct Design\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Concrete Moisture Probe when used with Tramex CME instruments operates on the principle that the electrical impedance of a material varies with its moisture content.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe CME instrument is pressed onto the CMP cradle which is pressed onto the material surface with the pins fully compressed and the probe inserted into the pre-drilled 19mm hole to measure the moisture content.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe electrical impedance is measured by creating a low frequency alternating electric field between the electrodes and the probe, to a depth of up to 10cm. This field penetrates the material under test. The very small alternating current flowing through the field is inversely proportional to the impedance of the material. The instrument detects this current, determines its amplitude and thus derives the moisture value.\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eOperating Procedure\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Determinator cradle should be flat on the slab surface and the Tramex Concrete Moisture Meter placed and firmly pressed onto the cradle with the pins fully compressed. The probe reads from the bottom, within the body of the slab, up to the surface.\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSize:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e43.5cm x 36cm x 14cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eWeight:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e2.6kg\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eABS Body\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMeasuring Range:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eMoisture Content for Concrete with Tramex CMEX5 and CMEX2:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0 - 6.9%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eMoisture Content for Concrete with Tramex CME5 and CME4:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e0 - 6%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDepth of Penetration:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3cm probe depth for concrete between 5-10cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e5.7cm probe depth for concrete between 10-15cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e8.3cm probe depth for concrete between 15-22cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e10.8cm probe depth for concrete between 22-28cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tramex","offers":[{"title":"Default Title","offer_id":40675774038209,"sku":"CDK","price":1715.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/3138\/8353\/products\/Tramex_20CDK_20Concrete_20Determinator_202_600x_4e8af283-faf7-40a0-a2b3-c12484752e13.jpg?v=1630899356","url":"https:\/\/moisturemeterexperts.com.au\/products\/tramex-cdk-concrete-determinator-kit","provider":"Moisture Meter Experts","version":"1.0","type":"link"}